CS-810

CS-810


Specifications
Details

Measurement of transparent or translucent materials

CS-810 transmission type liquid spectrophotometer is a high performance spectrometer specially designed for measuring liquid transmittance, absorbance, concentration, chromaticity and other parameters. The instrument adopts D/0 measurement structure and integrates technologies such as full-band light source, single grating optical path spectroscopy system and other real-time calibrations, so that the resolution of the instrument reaches 0.0001, the standard deviation of transmittance is within 0.08%, and the chromaticity value: ΔE*ab 0.015.

D / 0 structure is adopted
Suitable for liquid and glass color measurement
Platinum, cobalt and Gardner index -- characterization of liquid yellow degree
  • Suitable for color measurement of glass and liquid

    The CS-810 transmission spectrophotometer is a high-performance spectrophotometer designed to measure parameters such as light transmission, absorbance, concentration, and chromaticity of materials.

    It is suitable for transparent or translucent materials, such as glass and solutions.
     

  • UV enhanced silicon photodiode

    The measurement range is expanded from 0 ~ 100% to 0 ~ 200%
     

  • Platinum cobalt, Gardner chroma

    Platinum cobalt chroma is suitable for measuring the color of transparent or liquid close to platinum cobalt number. This color feature is usually transparent or brownish yellow

    Gardner Color Code is suitable for colors with darker yellow or brown color of platinum cobalt
     

  • Color management software

    It is convenient for quality monitoring and color data management of enterprises

    It can digitize users' color management, compare color differences, generate test reports, provide a variety of color space measurement data, and customize customers' color management
     

    Model
    CS-810
    Illumination
    Illumination: d/0 (diffused Illumination, 0 degree viewing) (conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition C standard)
    Integrating sphere
    Φ 40mm, avian-d fully diffuse surface coating
    Lighting source
    CLEDs(Full band balanced LED light source)
    Sensor
    Dual optical path sensor array sensor
    Wavelength range
    400nm-700nm
    Wavelength interval
    10nm
    Half band width
    5nm
    Test range
    0-200%
    Reflectance Resolution
    0.01%
    Observer angle
    2°/10°
    Illuminants
    A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84
    Data being displayed
    Transmittance graph/value, chromatic value, color difference values, color assessment results, color tendency, history color value simulation, manual input standard sample, generate measurement reports
     
    Measurement interval
    1S
    Measurement time
    1S
    Measuring aperture
    Φ10mm
    Color space
    CIELab,LCh,CIELuv,XYZ,Yxy,transmissivity,HunterLabMunsell,MI,CMYK
    Color difference formula
    ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00
    Other indices
    WI(ASTME313-00,ASTME313-73,CIE/ISO,Hunter,Taube Berger Stensby),
    YI(ASTMD1925,ASTME313-00,ASTME313-73),Tint(ASTME313-00),Isomorphism index milm,
    color fastness, color fastness, APHA, Pt Co, Gardner, Saybolt, astmcolor, Saybolt, ASTM Color
     
    Repeatability
    Transmittance, standard deviation within 0.08% Chromaticity value: ΔE*ab 0.015 (When measuring air 30 x at 5-second intervals after air calibration), max. 0.03
    Inter station difference※※
    ΔE*ab less than ≤0.2
    Data interface
    USB
    Store data
    Mass storage (PC)
    Light source lifetime
    5 years, 1.5 million tests
    Size
    475*340*150mm(L*W*H)
    Weight
    About 7kg
    Operating temperature
    0 ~ 45 ℃, relative humidity 80% or lower (at 35 ° C), no water vapor condensation
    Storage temperature
    -25 ° C to 55 ° C, relative humidity 80% or less (at 35 ° C), no moisture condensation
    Standard accessories
    Power line, color management software, driver software, data line, black correction board, 40 * 10mm, cuvette
    Optional Accessories
    40 * 33mm cuvette (for ASTM color), 40 * 100mm cuvette (measuring Saybolt)


    ※ After correction, measure the standard deviation of air for 30 times at an interval of 5S
    ※※ Maximum value of measurement results for 12 BCRA ceramic standard color plates

     


View more about CS-810 on main site